DAE Error -596 while recording to ISIS.
|
||
Avid Knowledge Base | ||
DAE Error -596 while recording to ISIS. |
DAE Error -596 may occur while recording if ISIS client and server versions do not match. |
Last Updated : February 11, 2013 Products Affected : ISIS, ISIS_5000, ISIS_7000, Pro_Tools_1_6, Pro_Tools_HD, Pro_Tools_LE, Pro_Tools_M_Powered
|
---|
After recording about 16 seconds of audio in a 48k Pro Tools session to an ISIS storage system, DAE error -596 is encountered. It is possible to record without limit in a 96k session, but when saving and closing the session, a Delayed Write File Error is encountered for Audio and Wavecache files associated with the session. |
This was observed in a system where the ISIS server was running version 3.2, but the Pro Tools system's client install was version 4.1. This may affect other mismatched version client/server configurations as well.
Please be sure that the ISIS server and clients are running the same software version number.