Knowledge base

DAE Error -596 while recording to ISIS.

Posted in Pro Tools

< Back to search Results
Avid Knowledge Base
DAE Error -596 while recording to ISIS.
DAE Error -596 may occur while recording if ISIS client and server versions do not match.

Last Updated : February 11, 2013
Products Affected : ISIS, ISIS_5000, ISIS_7000, Pro_Tools_1_6, Pro_Tools_HD, Pro_Tools_LE, Pro_Tools_M_Powered

After recording about 16 seconds of audio in a 48k Pro Tools session to an ISIS storage system, DAE error -596 is encountered.

It is possible to record without limit in a 96k session, but when saving and closing the session, a Delayed Write File Error is encountered for Audio and Wavecache files associated with the session.

This situation may be encountered if the ISIS client and server versions do not match.

This was observed in a system where the ISIS server was running version 3.2, but the Pro Tools system's client install was version 4.1. This may affect other mismatched version client/server configurations as well.

Please be sure that the ISIS server and clients are running the same software version number.

Read Full Article